2-18
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
a.
There is one control cable and two ribbon cables on the right side of the power
supply compartment, W21, W11 and W12. See Figure 2-5 for connection loca-
tions.
1.
Connect W12 to J4 on PS2.
2.
Pull the AC input and blower wires out of the cabinet where
they are out of the way of the power supply tray and can be
easily reached later. Carefully roll the power supply tray into
the cabinet.
3.
Connect W11 to J4 on PS1 near the front of the power supply
tray.
4.
Connect W21 to J6 on PS1 also near the front.
b.
AC input wires #1 and #2 (large orange cables tied up on the left side of the
power supply compartment) and gray blower wires #40 and #41 all connect to the
gray Wago block, 1A17TB1, on the front left side of the power supply tray. See
Figure 2-7. There are 6 terminals in A17TB1, with terminal #1 on the left and #6
on the right. Check the Overall System Block Diagram for proper wire connec-
tions to A17TB1.
c.
A1J2, the large gray connector near the front of PS2, can now be connected to
A1P2. See Figure 2-5.
d.
Connect the PS3/PS4 to PS1/PS2 interconnect cable. The cable is a small bundle
of wires that connects from J6 on PS2 in the left-hand cabinet, to J6 on PS3 in the
right-hand cabinet, see Figure 2-5. The bundle also has wire 210 bundled with it.
Wire 210 connects to 2A17A1TB1, a small Wago block on the side of the PS3
transformer. The cable bundle is shipped connected to PS1 and PS2. The cable
should be routed through the hole between the cabinets which is near the front of
the power supply compartment.
e.
Route the 4 large orange cables from PS3 and PS4 on the right-hand cabinet
through the same hole mentioned in the last step. The four cables all connect near
the top of the power supply compartment above PS1 and PS2. The wires connect
as follows: See Figure 2-6.
1.
Wire #680 connects to 1C7
2.
Wire #681 connects to 1C8
3.
Wire #652 and 752 connect to the ground studs underneath
the PA deck.
f.
Connect the equivalent cables for PS1 and PS2 as follows: See Figure 2-6.
1.
Wire #80 connects to 1C3
2.
Wire #81 connects to 1C4
3.
Wire #52 and 152 connect to the ground studs underneath the
PA deck.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...