4-48
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
•
UPS SET Screen [HOME, MORE, CONFIGURATION, B, A, B] Then choose the
desired modulation format to set the power level when the transmitter is operating on
a backup UPS or generator AC supply.
Once the operator has set a power level in kW in these screens, the controller uses the
OP_APC_Factor to find the DAC_APC_REF that would represent each of the power
levels and sets that number as the power level limit. This maximum DAC_APC_REF
setting is called DAC_MAX and is calculated for each mode from the formulas below:
For HIGH ON mode:
DAC_MAX = MAX HIGH SET (kW) / APC_Factor
For LOW ON mode:
DAC_MAX = MAX LOW SET (kW) / APC_Factor
For UPS mode:
DAC_MAX = UPS SET (kW) / APC_Factor
DAC_MAX [HOME, MORE, CONFIGURATION, C, B] is the display variable which
will contain one of the above numbers depending on which mode the transmitter is in.
Once these are set, the DAC_APC_REF in that mode can never go above the
DAC_MAX setting.
Example: If the transmitter is calibrated at 7000W (HIGH ON), and the desired MAX
Power setting is 7200W, this would be entered into the MAX HI SET screen.
Remember that for 7000W the nominal DAC_APC_REF is 660. The micro would now
use the formula:
DAC_MAX_HIGH = MAX HIGH SET (kW) / APC_Factor
DAC_MAX_HIGH = 7200 / 10.61 = 679
This is now the highest possible number for the DAC_APC_REF and will limit the
transmitter power to 7200. To prove that:
FWD PWR = APC Factor * DAC_APC_REF
FWD PWR = 10.61 * 679 = 7200W
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...