WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 6 Troubleshooting
6.12.17 IPA_LOAD, Fault
To check for bad RF Cables, the Master Controller checks Z-Plane currents for proper
IPA load balance. If a severe imbalance is found, the transmitter is muted.
6.12.18 PSC#_COMM, Fault
This fault means there is a communication failure between the Power Supply Controller
and the Master Controller. No action is taken when this fault is detected since the PS
Controller is designed to operate without the Master Controller. It is simply used to alert
the operator to the fault condition. All meter readings for 2 of the power supplies will be
replaced with an asterisk (*).
•
PSC#1 controls PS1 and PS4.
•
PSC#2 controls PS2 and PS3.
6.12.19 PAC#_COMM, Fault
This is a communications fault between one of the PA Controllers and the Master
Controller. No action is taken when this fault is detected since the PA Controllers are
designed to operate without the Master Controller. It is simply used to alert the operator
to the fault condition. All meter readings associated with that PA Controller will be
replaced with an asterisk (*). Table 4-3 on page 4-69 shows which PAs are associated
with each PA Controller.
6.12.20 AMB_WARNING, Ambient Temp Warning
If the ambient temperature exceeds 40°C, the controller will switch the fan to high
speed. If the temperature goes down after high fan speed is initiated, the fan will go
back to low speed when the ambient temperature reaches 35°C (the hysteresis between
40 and 35°C prevents the fan from quickly oscillating between low and high fan speed).
NOTE:
Ambient temperature is sensed with a thermistor on the IPA Backplane Board.
6.12.21 AMB_TEMP, Ambient Temperature Fault
There are 2 thresholds associated with this fault, 55 and 65°C. If the temperature
continues to rise at high fan speed, after an Ambient Warning, then at 55°C the
transmitter is muted. If the temperature exceeds 65°C, then the transmitter is shut off.
6.12.22 ISO_##, System ISO Over-Temperature
There are 7 system ISO loads in the Z16HD+ transmitter. These are designated:
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...