6-26
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 6 Troubleshooting
c.
If the thermistor is not open, turn the low voltage back on and check to see if
there is voltage across the thermistor. No voltage to the thermistor means an open
between the controller and the thermistor. Trace the connection back to the con-
troller board. Also, note that in this case the RFI boards have a series inductor
which may have opened.
6.12.2 EEPROM_DEF, EEPROM U39 Default Load
This fault means that when the controller loaded the transmitter settings from the
EEPROM U39 on the Master Controller, one or more of the values was considered to
be invalid or out of tolerance and was replaced with a Default value from the firmware
prom. This fault is an indication that the EEPROM U39 should be replaced. (Refer to
Section V, Maintenance and Alignments, for the replacement procedure). The only time
this fault should occur is when a new EEPROM U39 is being installed. In this case it is
random data and all defaults will be loaded automatically. However, after the first
default load it should never happen again.
6.12.3 REF_WARNING, +5V Reference Warning
This is simply a warning that the +5Vdc reference voltage, used for system software
calibration, is less than 4.75Vdc. No transmitter action is taken other than to report the
fault in the fault log and light the Fault LED on the front panel. The +5V Ref can be
checked at TP4 on the Life Support Board where it originates. It is adjusted with R28
also on the Life Support Board for +5.0Vdc.
6.12.4 MSTR_REF, +5V Reference Fault
This fault means that the +5V reference voltage, which comes from the Life Support
Board and is common to all of the controller boards, is less than 4.6V. This voltage is
used as the reference for all system calibration. A change in this voltage would cause
major errors in system calibration and overload settings and is therefore a critical fault.
The transmitter will be shut off. The +5V Ref can be checked at TP4 on the Life
Support Board and adjusted with R28 also on the Life Support Board.
If a PAC_REF fault appears along with the MSTR_REF fault, then the +5V reference is
most likely the problem. If only the MSTR_REF fault is present then the Master
Controller or a connection between the Life Support Board and the Master Controller
should be suspected. The +5V REF can also be checked at TP19 on the Master
Controller Board. Note that CR11 will 5Vdc to TP19 if the 5V REF has
failed, but with the diode drop it will be less than 4.6Vdc and adjusting R28 on the Life
Support Board will have no effect.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...