2-34
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
2.7.1.1
Extended Metering
Extended metering can also be connected to TB1 terminals. See Figure 2-15 for
extended metering connections.
Figure 2-15 Extended Metering
2.7.2
UPS/RFSOURCE Select: Configurable Input
The remote input at TB1-9 is a software configurable input which is set via the
Diagnostics Display Menu. It can be used as either a UPS Mode select input or as a
Remote RF Source select when a second RF source is installed in the transmitter. To
configure the input using the Diagnostics Display Menu press [HOME, MORE,
CONFIGURATION, A, A]. This should bring up the screen shown in Figure 2-16. The
default setting is shown as “UPS”. This means the input is ready to be used as the UPS
Mode select. To use TB1-9 as a Remote RF source select input press [C]. This will
switch the display to read “EXC”. This re-configures the TB1-9 input so that when it is
pulled low momentarily, the transmitter will switch to the other RF Source. This RF
source will be selected until the input at TB1-9 is pulsed low again.
NOTE:
This input is simply a switch command and does not care which exciter was on
the air to begin with. For example, if the Main exciter is on the air, then it will
switch to the alternate, but if the alternate is on the air it will switch to the main.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...