9/15/06
888-2586-001
5-31
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
STEP 4
Before removal, notice that the IC has one corner which is bevelled and
the IC socket has a pointer etched in the top which is pointing to the
bevelled corner. See Figure 5-10.
Figure 5-10 Top View of Firmware IC Socket
STEP 5
The manufacturers do make a special extraction tool for these type of
IC’s but it has been found that a sharp meter lead or ice pick actually
works better for extracting them. Place the sharp tool point into one of
the slots at the corners of the IC pry it up just a little. Then move to the
opposite corner and pry it up a little. Work back and forth from one
corner to the other until the IC comes out.
STEP 6
If the IC is going to be re-installed and you need to set it down, make
sure it is placed on an anti-static mat or in an anti-static bag.
5.16.2 Firmware IC installation:
STEP 1
To install the firmware IC’s, you first need to match the U## component
designator printed on the IC label with the proper socket on the board
(the socket has a label printed on the board). For example U18 and U28
are for the Master Controller and must be placed in the correct socket.
STEP 2
To install the IC, simply place the chip over the socket with the beveled
edge oriented correctly and press it in with your thumb. Be sure to press
evenly across the top of the IC.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...