4-44
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
transmitter at 25% of rated power. Proper setting of R25 requires an external wattmeter
and is covered in Section V, Maintenance under “Setting Life Support Power Level.”
!
CAUTION:
IN LIFE SUPPORT MODE THERE IS LIMITED OVERLOAD PROTECTION AND
NO FOLDBACK FUNCTIONS. ADJUSTING R25 TO MORE THAN 25% RATED
POWER WILL CAUSE THE TRANSMITTER TO SHUT OFF AND COULD
DAMAGE THE TRANSMITTER. REFER TO SETTING LIFE SUPPORT POWER
LEVEL IN SECTION V, MAINTENANCE.
4.8.2
Calibration Factors and A/D Values
The configuration menus in the Diagnostics Display contain the calibration factors and
A/D values used by the transmitter for calibration, operation and protection. The cal
factors are calculated by the micro when the transmitter is calibrated. The A/D readings
are the decimal equivalents of the forward and reflected power sample voltages.
These cal factors and A/D values will be dependent upon the hardware configuration
and modulation format of the ZHD+ transmitter. They are factory calibrated or have
been field calibrated at the rated transmitter power as detailed in the Maintenance
procedures. These numbers are stored in EEPROM, U39. The actual numbers
obtained during the factory calibration are recorded in the Factory Test Data.
NOTE:
If the transmitter is calibrated at a power level other than rated power, these num-
bers will change and their new values should be recorded.
It is important to note that as long as the hardware calibration of the forward and
reflected directional couplers is not disturbed, the Cal Factors could be entered
manually and the transmitter calibration would be within a few percent of the factory
calibration. To access the edit controls for each parameter, go to the screen containing
the value and press and hold the [D] button then press [C]. The edit controls should now
show up on the screen. The transmitter must be OFF to edit these numbers.
!
CAUTION:
ENTERING A WRONG VALUE IN ONE OF THESE SCREENS COULD CAUSE
SERIOUS DAMAGE TO THE TRANSMITTER OR EXTERNAL SYSTEMS. IT IS
RECOMMENDED THAT THESE NUMBERS BE OBTAINED BY FOLLOWING
THE CALIBRATION PROCEDURES AS OUTLINED IN SECTION V,
MAINTENANCE.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...