2-24
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
2.5.9.2
Failsafe Interlock Connection
To use the failsafe interlock connection, remove the jumper between TB1-8 to TB1-
10(GND), then connect failsafe interlock wires. A contact closure allows the transmitter
to operate. The Failsafe connection can be used for any application which requires
muting the transmitter RF output. When the failsafe interlock connection is open the fan
is set to high, the IPA and exciter are muted. The failsafe interlock wires can also be
connected directly to the Life Support Board at J4-7 and J4-8 if it is desired to have the
failsafe interlock completely separate from the remote control interface. The TB1 and
J4 connections are in parallel. Only one or the other is to be used. NOTE: The
transmitter will transmit when the failsafe interlock connection is restored (if it was
transmitting when the failsafe connection was opened).
2.5.10 RF Connections
The station transmission line may now be connected at the flange located on top of the
transmitter. Be sure the bullet seats correctly and all flange bolts are tight. Make sure
the clamp at the top of the harmonic filter is tightened.