WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
inside the Wago block and the wire can be inserted. Be very careful not to let the
wire ends fray. The wire insulation should actually extend just inside the Wago
block hole. Release the screwdriver to clamp the wire.
d.
The gray Blower wires #40 and *#41 also connect to the Wago block A17TB1.
See Overall System Block Diagram for connection to the proper A17TB1 termi-
nals (*Wire #41 is not used in 3 phase 4-wire systems).
NOTE:
It is very important that wires 1, 2, 3 and 40, *41 connect to the proper terminal
on A17TB1. If any one or more of these wires are in the wrong position, the
blower will probably not run (it depends on which phases are switched).
e.
The large orange ground wires coming from the top of each rectifier assembly
attach to the ground studs at the top-front edge of the power supply compartment.
The cable numbers are 46, 60, 246 and 260. The studs are located under the shelf
which separates the power supply from the PA compartment, see Figure 2-4.
f.
Connect the safety ground wire to the stud on the front of the power supply tray.
g.
Tighten the two hold down nuts located on the bottom front corners of the power
supply compartment and re-install the front cover panel for the power supply
compartment.
2.5.6
Single Phase Power Supply Installation
Before installing the power supply check the primary AC tapping on the power
transformers as outlined below. If the cabinets are shipped with the supplies installed
and both cabinets already bolted together then only a visual inspection of the supplies
and their connections is required. In some cases the transmitter will be shipped with
both supplies installed, but the cabinets may be separated. In this case only the cabinet
interconnects will have to be made. See Figure 2-5 and 2-5 below and Steps (d.) and (e.)
under Installing PS1 and PS2.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...