Excitation Voltage: 25 VDC or VAC Max.
Potentiometer Resistance: 1000 ohms ±10%

Note:  Any input voltage up to the maximum specified above 
may be used.  However, for best performance, the input 
voltage should be closely regulated to insure a stable and ac-
curate output voltage.

*

*

* 1.56 (39.6 mm) with "DS" option.

* 1.56 (39.6 mm) with "DS" option.

Wiring and Circuit Diagram

4175 SW Research Way, Corvallis, Oregon, 97333

•Tel: (541) 757-3158 •Fax (541) 757-0858

PA Series Installation Guide

Model PA

Ranges to 50" (1250 mm)

Ranges to 80" (2000 mm)

Dimensional Information

Range

“A”

(in.)   (mm.)

2”, 10”

0.66

16.8

3”, 15”, 30”

0.51

12.9

4”, 20”, 40”

0.35

8.8

5”, 25”, 50”

0.19

4.8