5-92
G650 Generator Protection & Control System
GEK-113285A
5.5 CONTROL ELEMENTS
5 SETTINGS
5
Figure 5–21: FUSE FAILURE ELEMENT BLOCK DIAGRAM
5.5.7 PULSE COUNTERS
The G650 includes eight pulse counters, each pulse counter stores the activation number of the input set to that pulse
counter. This value can be multiplied for a factor selectable by setting.
The inputs used in this pulse counter function can be selected from all the available in the G650 device. Take into account
that the input/output settings are both set for the generic input as well as for the pulse counter input, e.g. Debounce time.
The settings for this function can be found at
Setpoint > Control Elements > Pulse Counters
Table 5–87: PULSE COUNTERS SETTINGS
Pulse Counters settings are:
CntPulses Enabled:
Enable/disable each pulse counter.
CntPulses Name:
Each pulse counter can have a configurable user name.
CntPulses Factor:
This is the factor multiplier applied to the input activations number stored in the
pulse counter, providing possibilities to adjust the obtained value to any scale. It the
"CntPulses Factor X" is set to zero it will take no effect.
SETPOINT > CONTROL ELEMENTS > PULSE COUNTERS
SETTING DESCRIPTION
NAME
DEFAULT VALUE
STEP RANGE
Pulse counter enabling setting
CntPulses Enabled X
DISABLED
N/A
[DISABLED – ENABLED]
Name of the pulse counter
CntPulses Name X
Pulse Counter X
N/A
N/A
Multiplier factor for the pulse counter
CntPulses Factor X
1.000
0.001 [0.000 : 65000.000]
Overflow value for the pulse counter
CntPulses Overflow X
65535
1
[0 : 1000000]
Board selection for the pulse counter
CntPulses Board Origin X
F
N/A
[F,G,H,I]
Input index inside the selected board
CntPulses Input Origin X
1
1
[1 : 32]
Note: X is the pulse counter index, up to 8.
Содержание Multilin G650
Страница 9: ...8 G650 Generator Protection Control System GEK 113285A TABLE OF CONTENTS ...
Страница 29: ...1 20 G650 Generator Protection Control System GEK 113285A 1 4 650 HARDWARE 1 GETTING STARTED 1 ...
Страница 293: ...5 150 G650 Generator Protection Control System GEK 113285A 5 9 LOGIC CONFIGURATION PLC EDITOR 5 SETTINGS 5 ...
Страница 391: ...11 6 G650 Generator Protection Control System GEK 113285A 11 4 RELAY CONFIGURATION 11 FREQUENTLY ASKED QUESTIONS 11 ...
Страница 426: ...GEK 113285A G650 Generator Protection Control System A 31 APPENDIX A A 1 LOGIC OPERANDS A ...
Страница 427: ...A 32 G650 Generator Protection Control System GEK 113285A A 1 LOGIC OPERANDS APPENDIXA A ...
Страница 587: ...C 22 G650 Generator Protection Control System GEK 113285A C 8 ANALOG INPUTS APPENDIXC C ...
Страница 595: ...D 8 G650 Generator Protection Control System GEK 113285A D 5 IEC 60870 5 104 POINT LIST APPENDIXD D ...
Страница 606: ...GEK 113285A G650 Generator Protection Control System E 11 APPENDIX E E 1 FACTORY DEFAULT LOGIC E ...
Страница 607: ...E 12 G650 Generator Protection Control System GEK 113285A E 1 FACTORY DEFAULT LOGIC APPENDIXE E ...
Страница 639: ...G 2 G650 Generator Protection Control System GEK 113285A G 1 GE MULTILIN WARRANTY APPENDIXG G ...