GEK-113285A
G650 Generator Protection & Control System
4-25
4 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES 4.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE
4
Table 4–19: ACTUAL VALUES RELATED TO RECORDING FUNCTIONS IN THE RECORDS STATUS MENU:
4.1.9.3 METERING
The Metering menu includes all the measurements available in the device. Primary and secondary values, and also the
data related to the recording functions in the relay.
Table 4–20: GENERAL OVERVIEW OF METERING MENU:
4.1.9.4 INPUTS/OUTPUTS
The Inputs/Outputs menu includes all the inputs and outputs signals available in the device. Contact and virtual type.
Table 4–21: GENERAL OVERVIEW OF INPUTS/OUTPUTS MENU:
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
RECORD
STATUS
Fault Reports
This menu shows the fault report status signals, as fault report trigger,
fault date, fault type and location, besides the fault report number.
Control Events
Status of the control events (if the signal configured to launch the control
event is active or not).
Oscillography
Status of signals related to oscillography recording, such as status or
digital channels, oscillography trigger, number of records available, etc.
Data Logger
Data logger information about oldest and newest sample time stamp,
and number of channels and days configured in data logger settings.
Demand
Demand trigger and reset inputs status.
Energy
Freeze, unfreeze and reset input signals for energy counters.
Breaker Maintenance
All signals related to breaker maintenance, such as number of openings,
closings, (KI)
2
t counters, alarm signal for (KI)
2
t, etc.
METERING
Primary Values
Primary values measurements for currents, voltages, power, energy and
demand
Secondary Values
Secondary values measurements for currents, voltages and power.
Phasor Diagram
Current, voltage and sequence components.
Frequency
Line and Bus frequencies.
INPUTS/
OUTPUTS
Contact Inputs
Status of digital inputs in the Relay for each board according to the relay
model.
Contact Output Status
Status of digital outputs in the Relay for each board according to the relay
model.
Contact Outputs
Operates
Status (activated or not) of the variables used to operate a contact
output. To configure these signals go to “Setpoint>Relay
Configuration>Outputs” menu.
Contact Outputs
Resets
Status (activated or not) of the variables used to reset a contact output.
To configure these signals go to “
Setpoint>Relay Configuration>Outputs
”
menu. This output reset Command will only be effective if the “
latch
”
option has been Selected for the “
Output Type
” setting on the I/O board,
thus when the contact output has been configured to emulate function 86
(latching relay).
IO Board Status
Status of I/O boards. This status provides if the hardware it is OK (boards
matching relay model, correctly inserted in their tracks, in good state and
communicating through the internal CAN Bus).
Virtual Inputs
Status of Virtual inputs latched (32) and self-reset (32).
Virtual Outputs
Status of virtual outputs (configured in PLC Editor). Up to 512.
Analog Inputs
Measurements coming from analog inputs (DCMA)
Содержание Multilin G650
Страница 9: ...8 G650 Generator Protection Control System GEK 113285A TABLE OF CONTENTS ...
Страница 29: ...1 20 G650 Generator Protection Control System GEK 113285A 1 4 650 HARDWARE 1 GETTING STARTED 1 ...
Страница 293: ...5 150 G650 Generator Protection Control System GEK 113285A 5 9 LOGIC CONFIGURATION PLC EDITOR 5 SETTINGS 5 ...
Страница 391: ...11 6 G650 Generator Protection Control System GEK 113285A 11 4 RELAY CONFIGURATION 11 FREQUENTLY ASKED QUESTIONS 11 ...
Страница 426: ...GEK 113285A G650 Generator Protection Control System A 31 APPENDIX A A 1 LOGIC OPERANDS A ...
Страница 427: ...A 32 G650 Generator Protection Control System GEK 113285A A 1 LOGIC OPERANDS APPENDIXA A ...
Страница 587: ...C 22 G650 Generator Protection Control System GEK 113285A C 8 ANALOG INPUTS APPENDIXC C ...
Страница 595: ...D 8 G650 Generator Protection Control System GEK 113285A D 5 IEC 60870 5 104 POINT LIST APPENDIXD D ...
Страница 606: ...GEK 113285A G650 Generator Protection Control System E 11 APPENDIX E E 1 FACTORY DEFAULT LOGIC E ...
Страница 607: ...E 12 G650 Generator Protection Control System GEK 113285A E 1 FACTORY DEFAULT LOGIC APPENDIXE E ...
Страница 639: ...G 2 G650 Generator Protection Control System GEK 113285A G 1 GE MULTILIN WARRANTY APPENDIXG G ...