EMS Operation
SkyView Pilot’s User Guide - Revision M
5-9
On the Engine Page: Widgets for VP-X measured battery voltage, VP-X measured starter
status, and VP-X fault status can be added to any of the EMS pages via the EMS SETUP >
SCREEN LAYOUT EDITOR.
Displaying the VP-X Page
The VP-X page is displayed on-demand by pressing MAIN MENU > ENGINE > VP-X. In addition to
bringing up the VP-X page alongside the Engine Page, this will also bring up the VP-X menu
along the bottom of the display. Once in the VP-X menu, pressing BACK will both close the VP-X
page and back out of the VP-X menu.
Because the VP-X page is part of the Engine Page, the Engine Page must be visible on the
display that you are trying to access the VP-X page on. The ENGINE page can be toggled on and
off on a display by pressing MAIN MENU > SCREEN > EMS PG.
The Engine Page dynamically resizes to accommodate the VP-X page alongside of it. If all of the
PFD, Engine, and Map Pages were being displayed when the VP-X page is toggled on, the Map
Page will automatically be removed to accommodate the VP-X page. When you turn the VP-X
page off, the Map Page will automatically be re-opened.
Figure 50 - VP-X Page with Fault
Graphical Electrical System Diagram
The top portion of the VP-X page depicts the following information about your aircraft’s
electrical system graphically:
Center, bottom (Vertical Power logo): Total current draw of all circuits in the system.
Yellow cautions and red warning levels are triggered at the values specified during
setup.