Appendix A: SkyView System Specifications
SkyView Pilot’s User Guide - Revision M
10-5
Connections
(1) 3 pin power
Charge Behavior
SkyView Display voltage above 12.25V: SkyView runs on
aircraft power; SV-BAT-320 is charged.
SkyView Display voltage above 10V, but below 12.25 V:
SkyView runs on aircraft power, but SV-BAT-320 is not
charged (standby mode).
SkyView Display voltage 10V: SkyView system runs on SV-
BAT-320; SV-BAT-320 discharges.
Autopilot Servo Quick Specifications
SV32 Mechanical
2.47” wide x 4.20“ tall x 3.98” deep (63 x 107 x 101 mm)
2 lbs (0.91 kg)
SV42 Mechanical
2.47” wide x 5.13“ tall x 3.98” deep (63 x 130 x 101 mm)
3 lbs (1.36 kg)
SV52 Mechanical
2.47” wide x 6.05“ tall x 3.98” deep (63 x 154 x 101 mm)
4 lbs (1.81 kg)
Operating Temperature
-22° to 167° F (-30° to +75° C)
Connections
(1) Power wire
(1) Ground wire
(1) SkyView Network Port (4 unterminated wires, no
connector)
(1) AP Disengage / Control Wheel Steering Button
(unterminated wire, no connector)
SV32 Torque
36 inch pounds
SV42 Torque
55 inch pounds
SV52 Torque
72 inch pounds