Appendix A: SkyView System Specifications
10-4
SkyView Pilot’s User Guide - Revision M
Sensor Inputs
(2) Voltmeters (0 to 30 volts DC)
(11) General Purpose
(3) General Purpose Enhanced
(2) Fuel Flow
(1) Amps (differential)
(1) Manifold Pressure
(2) General Purpose Thermocouple (SV-EMS-220 only)
(Left and Right) RPM
(Left and Right) RPM
(6) CHT
(6) EGT
(1) CAN Bus for Rotax 912 iS (SV-EMS-221 only)
Other Inputs, Outputs,
and Communication
Ports
(1) +12 volt DC auxiliary sensor power output
(1) +5 volt DC auxiliary (fuse limited at 500 mA) sensor
power output
(1) SkyView Network Port
(1) External Alarm Light Output
SV-GPS-250 Quick Specifications
Mechanical
2.19” wide x 0.75” tall x 3.44” deep (56 x 19 x 88 mm)
6.7 oz (0.19 kg)
Operating Temperature
-40° to 140° F (-40° to +60° C)
Connections
(1) Power wire
(1) Ground wire
(1) Serial TX (NMEA format; 5 Hz update rate)
(1) Serial RX
SV-BAT-320 Quick Specifications
Mechanical
3.30” wide x 2.10” tall x 3.90” deep (162 x 28 x 76 mm)
9.6 oz (0.27 kg)
Operating Temperature
Charge:
32° to 113° F (0° to +45° C)
Discharge:
-4° to 140° F (-20° to +60° C)