Chapter 6. Manage / Configure the Switch
109
Follow the steps to configure ...
a.
Set “Unit” first. It could be selected from pre-defined units, or define by user. Click [Apply] after the setting.
b.
Select the Port Number.
c.
Enter the rate limit level for Ingress and Egress traffics. “0” means NO LIMIT. Click [Apply] after the setting.
About “Packet Drop for Ingress Limit” function ...
When Ingress traffic rate exceeds Ingress Rate Limit, the switch can drop packets or pause the traffic. If packet drop is
enabled, flow control of ports will be disabled and packets could be dropped. If packet drop is disabled, flow control of
ports will be enabled and pause frame will be sent when ingress traffic rate exceeds the limit.
5-2) Storm Control Configuration
This function can setup the broadcast, multicast, and unicast storm rate of the switch.
Please follow the rules in table to setup the maximum storm rates.
Note:
The storm rate is counted by pps (packet per second).