A 128 XR - A 122 X
-62-
©
C.F.M.
S.p.A.
Tutti i diritti riservati /
All rights reserved
Tous droits réservés /
Nos reservamos todos los derechos
1- Clogged filter
1- The feeder does not load
the product
Remedies
Fault
Cause
1- Make sure that the prod-
uct has not clogged the
discharge gate
1- Replace the seals (see
sub-section 7.5.1)
1- Check the condition of the
seals
1- Clean the tube
2- Loading time too short
2- Reduced loading capacity
1- Clean the filter (see sect.
7.8)
1- Discharge gate still open
1- Worn or broken seals
1- Hopper not hermetically
closed
1- Clogged pick-up tube
2- Increase the time
(see par. 7.6).
2- Clogged filter
2- Product has stuck inside
the pick-up tube
2- Frequently clean or wash
the tube to prevent prod-
uct from accumulating in-
side
2- Increase the cleaning
time
3 - The feeder does not di-
scharge the product
3- Hopper of the supplied
machine full
3- Wait until it empties
8
Troubleshooting