COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
37
Important Information
Product Details
Basic Assembly and Extensions
Note:
One internal S
0
port corresponds to two internal subscriber connec-
tions in this case.
An S
0
or U
P0
port set to the option
free
in the port configuration under
Appli-
cation
is not considered in the calculation of this limit.
The PBX can be operated with a maximum of 14 external analogue, VoIP and ISDN channels.
Maximum number of modules:
•
COMpact 2FXO module: 3
•
COMpact 4FXS module: 4
•
COMpact 2BRI module: 5
•
COMpact 4DSP module: 1
Maximum number of separate ports/channels:
•
External S
0
ports: 3
•
Internal S
0
ports: 10
•
Internal U
P0
ports: 10
•
External analogue ports: 6
•
Internal analogue ports: 16
•
External VoIP channels: 14
•
Internal VoIP channels: 16
•
Voice mail/fax channels: 8
Note:
An S
0
port corresponds to two ISDN channels.
Maximum number of additional devices:
•
IP switch relays: 10
•
Announcement outputs (e. g. Auerswald a/b Audioboxes): 8
•
a/b and IP door terminals: 8
•
Relays/actuators (as part of IP switch relays, a/b Audioboxes, a/b and IP door terminals): 24
Note:
The PBX can be operated with 8 additional relays, if these relays are
configured only with the operating modes speaking, second ringer and slave
relay.