304
COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Functions
Alarm
Alarm
If the PBX function alarm is used in case of an alarm, internal and external telephones can be
called and sirens can be switched on.
The alarm sequence can be as follows:
•
Alarm detection via a switch input (optional, see chapter Important Information > Product
Details > Basic Assembly and Extensions) or via an internal call.
•
The set alarm delay time is running (0-99 seconds).
•
Non-recurring start of for example a siren via a relay/actuator (optional, see chapter
Important Information > Product Details > Basic Assembly and Extensions).
•
At the same time, the first alarm call run starts (alarm calls to the alarm subscribers) by
calling the first alarm subscriber for approx. 60 seconds. Internal alarm subscribers are
called with a special ringtone (telephone-dependent). After picking up the receiver, you
repeatedly hear an alarm announcement stored in the PBX. The called party must
acknowledge the alarm call within 60 seconds by sending the DTMF number 0.
•
If the called party does not acknowledge the alarm call, the next alarm subscriber is called
a few seconds after the first call is finished. And so on....
•
If all the alarm subscribers have been called without receiving an acknowledgement, the
alarm loop is repeated after a configurable alarm waiting period (0-99 seconds) has elapsed
(up to 9 times).
•
The alarm is terminated (and relays assigned to the alarm are switched off) as soon as one
of the alarm subscriber acknowledges the alarm. If the alarm input has been configured to
Active once
, it is disabled afterwards. If the alarm input has been configured to
Active
repetitive
, it is enabled again and a new alarm can be triggered.
Proceed as follows for configuration:
•
Creating an alarm with an internal number.
–
Using the configuration manager (page
Devices > Alarms
)
•
Creating a switch input and assigning it to the alarm.
–
Using the configuration manager (page
Devices > Alarms
)
•
Creating a relais and assigning it to the alarm.
–
Using the configuration manager (page
Devices > Alarms
)
•
Managing and assigning audio files for announcements.
–
Using the configuration manager (on the following pages)
– Functions > Music on Hold/Announcements > File management