COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
459
Functions
Relays (Actuators)
Creating a Relay
6. Enter the IP address required by the connected device in the
IP address
entry field.
Possible entries:
7. Enter the port required by the connected device in the
Port
entry field. Possible
entries:
Note:
Normally, the default port is port 80.
8. Enter the user name required by the connected device in the
User name
entry field.
9. Enter the password required by the connected device in the
Password
entry field.
10. Enter the names of the relays in the
Name
entry field.
Note:
Relays which are offered in the device template, but are not needed,
can be deleted. To do so, click
.
11. Click
Save
.
12. Click
Close
.
Note:
To change the settings for the IP switch relay created in this way, click
Configure
in the line of the corresponding IP switch relay on the page
Devices > Device wizard
.
To create further configurations for the relays, open the page
Devices >
Relays (Actuators)
. The configuration is described in the following.
To reset the IP switch relay to the default settings of the device template,
delete the IP switch relay on the page
Devices > Device wizard
and create
the IP switch relay again.
Creating a Relay
Relays can have various functions on the PBX. For a detailed description of the operating
modes, refer to the chapter Functions > Relays (Actuators) > Relay Operating Modes.
IP address with a range of 0 to 255 (example: 192.168.0.240)
1
to
65535