COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Installation and Commissioning
ISDN End Devices
Connecting the Cable and the Wall Sockets to the Internal S
0
Port (Internal S
0
Bus)
1. Lay the lines according to the selected bus variant.
2. Attach the wires to the four terminal clamps at the internal S
0
port.
Note:
When assigning the individual wires, orient yourself with the identifiers
subsequently listed or refer to VDE 0815 when identifiers deviate.
3. Connect the IAE or UAE8 sockets to the terminal clamps at the internal S
0
port.
The figure below shows the wiring of the terminal clamps with different wall sockets
(IAE and UAE8) in a diagram, as well as the position of the terminators in the last wall
socket.
Warning:
Power surges, which can occur during electrical storms, can
cause life-threatening electric shocks or damage or destroy the PBX.
•
Hire a qualified electrician to lay the cables within the building.
Note:
For a structured cable installation configured on the COMpact
5000R, CAT 5 cables and CAT 5 wall sockets are used instead of the
cables and wall sockets listed here. To connect an analogue device, a
commercially-available RJ-45/TAE adapter is required.
Important:
For a structured cable installation on the COMpact 5000R, the
line length of all applicable end devices must be taken into account.
Cable with Two
Twin Wires
Cable with Star Quad
Physical circuit/
pair 1
a1
b1
red
black
without ring
single rings, 17 mm spacing
Physical circuit/
pair 2
a2
b2
white
yellow
double rings, 34 mm spacing
double rings, 17 mm spacing