x330 Series Installation Guide for Virtual Chassis Stacking
157
Depending on how you power on or reboot the stack in the future,
the switches might select a different master. That does not change
their ID numbers, their configurations, or the manner in which you
manage the stack.
3. Do one of the following:
To set the switch priority values, continue with the next step.
Setting priority numbers is optional. Assigning switches unique
priority numbers can protect the configuration of the stack when
adding new switches, as well as establish the order in which
member switches become the master switch, if necessary. For
background information, refer to the “STACK PRIORITY
Otherwise, go to Chapter 14, “Cabling the Networking Ports” on
page 185, to complete the installation.
4. Enter the ENABLE and CONFIGURE TERMINAL commands to move
to the Privileged Exec mode: Refer to Figure 76.
Figure 76. Moving to the Global Configuration Mode with the ENABLE and
CONFIGURE TERMINAL Commands
5. Enter the STACK PRIORITY command to set the priority numbers.
The command has this format:
stack
ID_number
priority
priority
You can change the priority number of only one switch at a time. The
parameters are as follows:
The ID_NUMBER parameter is the ID number of the switch whose
priority value you are setting. The range is 1 to 8. Switches display
their ID numbers on the ID LEDs on the front panels.
The PRIORITY parameter is the new priority value for the switch.
The range is 0 to 255. The default is 128. The lower the number,
the higher the priority.
The stack will be easier to manage if the priority number of a switch is
the same as its switch ID. Here are two examples. To assign the
priority value 1 to the switch with the ID number 1, you enter:
awplus(config)# stack 1 priority 1
awplus> enable
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
awplus(config)#
Содержание AT-x930-28GPX
Страница 8: ...Contents 8...
Страница 12: ...Tables 12...
Страница 16: ...Preface 16...
Страница 82: ...Chapter 2 Virtual Chassis Stacking 82...
Страница 92: ...Chapter 3 Beginning the Installation 92...
Страница 102: ...Chapter 4 Installing the Power Supplies 102...
Страница 118: ...Chapter 7 Installing the Switch in an Equipment Rack 118 Figure 53 Attaching the Equipment Rack Brackets...
Страница 124: ...Chapter 8 Installing the Switch on a Wall 124 Figure 58 Minimum Wall Area Dimensions with the Front Panel on the Right...
Страница 214: ...Appendix A Technical Specifications 214...