Sync Loss Seconds
The sync loss seconds in this example may have been caused by high
bursts of errors or momentary clock loss. The clock signal from a clock
recovery module may have momentarily ceased. To confirm periods of
momentary clock loss, check the measurement log file.
In this example, the analyzer was in auto sync mode. If the analyzer was
in manual sync mode, the results would not have been measured and
displayed in the same way.
When the clock signal resumed, the received and ED reference patterns
could only be aligned if the synchronization functions were activated.
In manual sync mode, this would not have happened because
synchronization functions are only activated manually.
In manual sync mode, sync loss and high BER would have been
measured from the start of the momentary clock loss to the end of the
accumulation period.
Data in this measurement log file confirms that there were periods of
momentary clock loss.
Solving Problems
8
Agilent J-BERT N4903 High-Performance Serial BERT
381
Possible Cause
Additional Information
Example Log of Sync and Clock Loss
Содержание J-BERT N4903
Страница 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Страница 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Страница 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Страница 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Страница 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Страница 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Страница 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...