5
Advanced Analysis
Advanced Analysis - Concepts
The Serial BERT offers several different kinds of advanced
measurements for various purposes:
This type of measurement is used to measure the timing and jitter
behavior for a device under test (DUT). It uses a bit error rate (BER)
measurement to evaluate the shape of the eye for the output signal of
the DUT. It also analyzes the jitter, separates the random jitter and
deterministic jitter components, and estimates the total jitter.
A direct result is the determination of the optimum sampling point delay
for receiving data from the DUT with maximum confidence.
DUT Output Timing/Jitter includes the Fast Total Jitter measurement
that can be used to measure the total jitter for devices which generate
a very low error density in a reasonable time span.
The Output Levels measurement allows you to characterize the behavior
of the output levels of a device under test (DUT). The sampling delay is
fixed. The error detector's decision threshold is automatically swept
within a user-defined range.
A direct result is the determination of the optimum decision threshold
level for receiving data from the DUT with maximum confidence.
The Eye Opening measurement generates a three-dimensional bit error
rate (BER) diagram as a function of the sample delay and the sample
threshold. With this measurement, the complete eye of the DUT output
signal is measured. The results comprise the voltage and timing of the
eye opening and the optimum sampling point.
The Error Location Capture measurement allows to capture the actual
position of errored bits in a memory-based pattern. The instrument
searches for the first bit errored in the incoming bitstream and marks
Agilent J-BERT N4903 High-Performance Serial BERT
User Guide
s
Agilent Technologies
159
S
DUT Output Timing/Jitter
Output Levels
Eye Opening
Error Location Capture
Содержание J-BERT N4903
Страница 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Страница 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Страница 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Страница 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Страница 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Страница 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Страница 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...