Explanation of the Numerical Results
The measurement provides numerical results for:
The output timing measurement parameters are defined in the following
table:
Table 21
Parameter
Description
Definition
Optimal Sample Point
Delay
The average of the left (A)
and right (B) bathtub/BER
threshold intersections.
(A+B)/2
Phase Margin
The period of time where
the bit error rate is lower
than the BER threshold.
B-A
The A and B values are the left and right intersections of the bathtub
curves with the BER threshold. Obviously, all values change if the BER
threshold is modified.
The following illustration shows an example for a measurement.
N O T E
This graphical view is not available in the measurement software.
The jitter measurement parameters are defined in the following list.
N O T E
All jitter measurement parameters (except the Total Jitter RMS and Total Jitter
Mean) change with the BER threshold.
5
Advanced Analysis
192
Agilent J-BERT N4903 High-Performance Serial BERT
Output Timing Measurement
Parameters
Jitter Measurement Parameters
Содержание J-BERT N4903
Страница 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Страница 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Страница 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Страница 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Страница 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Страница 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Страница 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...