11-48 ADS
Manual
Problem
Monitor independently discontinues logging data.
Possible
Causes
Battery pack may be dead or below minimum voltage
requirement
(7.5 volts - internal).
3.3-volt (yellow) fuse on regulator may have blown.
Monitor memory may have been corrupted during
firmware upgrade, causing the monitor to record data
only during monitor communications.
Possible
Solutions
Replace battery pack.
Replace the 3.3-volt (yellow) fuse on the regulator.
If the monitor is logging data only during monitor
communications following a firmware upgrade, contact
your ADS regional representative to clear the monitor
memory and reactivate the monitor.
Contact your regional ADS representative.
Problem
An I/O error message displays when communicating
with the monitor.
Possible
Causes
Communication quality might be marginal.
Antenna may be defective.
Processor board may be faulty.
Possible
Solutions
Re-attempt communication with the monitor.
Temporarily attach new antenna, and permanently
replace the existing antenna if the error message no
longer occurs.
Replace the monitor if defective.
Contact your regional ADS representative.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...