5-61 ADS
®
Manual
Selecting an Installation Location
Manhole structures with the following characteristics facilitate the
installation of Long Range Depth Sensor:
z
Manhole depth between 3 and 21 feet (914
–
6400 mm)
Note:
The maximum range of the Long Range Depth
Sensor is 20 feet (6096 mm). Ensure the distance between
the bottom of the sensor and the manhole invert does not
exceed this distance.
z
Manhole invert visible from street or ground surface
z
Manhole with rungs (
If there are no rungs in the manhole, drill
an anchor point into the manhole wall to secure the tether and
therefore the Mounting Bar in case it becomes dislodged.)
z
An iron manhole frame with a diameter between 21 inches
(530 mm) and 28 inches (710 mm) and a frame depth of 3
inches (76 mm) or more. Manhole frames greater than 28
inches (710 mm) in diameter require the use of Extension
Rods. See page 5-64,
Installing the Mounting Bar
, for more
details.
Note:
Manhole locations that do not meet characteristics
mentioned above will require special mounting techniques
and possible manhole descent.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...