
5-6 ADS
Manual
bracket positioned above the crown of the pipe on the
manhole wall.
z
Pipe Height and Width
Measure and record the horizontal
and vertical pipe dimensions carefully. Inaccurate pipe
measurements
—
even slightly inaccurate measurements--can
skew and misrepresent flow data.
z
Pipe Shape
Taking the appropriate measurements that
precisely reflect the exact pipe shape is essential to obtaining
accurate flow calculations. Therefore, irregularly shaped pipes
will require additional measurements. Refer to the
Q
start
XML
online help for more information.
Note:
All relevant pipe dimensions and measurements
are required for entry in the
Q
start
XML
software during
monitor configuration and activation. The software
primarily requires pipe shape, height, and width during
these activities.
z
Manhole Depth
Measure the distance from the rim to the
manhole invert. Distances beyond 30 feet could require
extension cables for the ParaDepth, ParaFlow, Peak Combo,
Smart Depth and Surface Combo sensors.
See Appendix B.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...