Sensor Installation and Connection 5-77
Surcharge Mount
1.
Determine the appropriate height at which to mount the
Ultrasonic Depth Sensor portion of the surcharge bracket
(ADS p/n I40-0010). The sensor attaches to the sliding adapter
bracket (ADS p/n 8000-0299) that slides into the groves of the
mounting plate at the lower portion of the surcharge bracket.
When making this determination, keep in mind that the
maximum range of the sensor is 10 feet (3.05 m).
2.
Press the bracket firmly against the manhole wall.
3.
Identify the three pre-drilled holes at the top of the bracket, and
spot drill the manhole wall through the middle hole with a drill.
4.
Remove the bracket, and drill and mount a ¼-inch x 2 ¼-inch
(M6 x 55-mm) anchor bolt.
5.
Secure the top of the bracket to the manhole wall with a washer
and nut.
6.
Push up on the bottom portion of the bracket until the sensor
portion of the bracket is level.
7.
Hold the bracket firmly in place against the manhole wall.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...