Sensor Installation and Connection 5-11
Quantity
Description
ADS P/N
15
¼-in. (7mm x 400mm) anchor cable ties
1
18-inch (457-mm) stainless steel crank handle
I10
–
0012
1
Models 8000-FST-IM-4WW-XXX include the 12-volt battery pack; Models 8000-
FST-IM-EP-4WW-XXX (
for external power
) do not include the battery pack.
2
IS pressure depth transducers (indicated by
—
xx- in the part number) are available
in Peak Combo Sensors and Surface Combo Sensors in 0
—
5 psi (0
—
0.34 Bar), 0
—
15 psi (0
–
1.03 Bar), and 0
—
30 psi (0
—
2.07 Bar) pressure ranges. Example:
a Peak Combo Sensor with a 0
–
15 psi (0
–
1.03 Bar) pressure transducer would be
specified in psi:
8K-CS4-15-35
.
3
Extension cables can be ordered to specific lengths up to 300 ft. (91m). Note the
desired length (
in feet
) in the
–
xxx
portion of the part number.
Standard
lengths are
10 ft. (3.0m), 25 ft. (7.6m), 50 ft. (15.2m), 75 ft. (22.8m), 100 ft. (30.5m), 125 ft.
(38.1m), 150 ft. (45.7m), and 200 ft. (61.0m). All other lengths must be custom
ordered.
4
The external power/communications cable and the ground cable included in the
external power grounding kit can be ordered to specific lengths up to 800 ft. (243m).
Note the desired length (
in feet
) in the
–
xxx
portion of the part number. Standard
lengths are 10 ft. (3.0m), 25 ft. (7.6m), and 100 ft. (30.5m). All other lengths must
be custom ordered.
Gathering Tools and Equipment
Gather the following tools for the installation:
z
Battery-powered hammer drill with assorted bits
–
including
the following at a minimum:
¼-inch (6-mm) x 6-inch (150-mm) masonry bit
3/8-inch(10-mm) x 4-inch (100-mm) [minimum length]
masonry bit
5/16-inch (8-mm) carbide-tipped bit
z
Heavy 4-pound (1.5-Kg) hammer
z
Rubber mallet
z
24-inch (610-
mm) carpenter’s level
z
Nut driver or socket set (English plus 13-mm for canister
hardware)
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...