5-22 ADS
Manual
z
AV|Gated Sensor
Mount the sensor as close as possible to
the six o’clock position (bottom).
The sensor
must be within
+/- 5 degrees of the bottom center of the pipe
. AV|Gated
sensors should not be installed in pipes with silt. If necessary, a
Silt Mount Adapter
can be used to mount the sensor 30 degrees
up the left of the pipe (the 7:00 position) when a higher
elevation is necessary. However, keep in mind that a physical
offset measurement must be taken when mounting the sensor in
any position outside the bottom of the pipe. Refer to
Installing
the Ring in the Pipe
on page 5-28
z
AV|Max Sensor
Mount the sensor as close as possible to the
six o’clock position (bottom), provided it is mounted above the
level of any silt present at the bottom of the pipe. Any silt
covering the sensor could interfere with the sensor signals,
potentially producing inaccurate or erroneous readings.
To avoid silt, the AV|Max sensor can be rotated as much as 15
degrees up left side of the pipe without using a special
mounting device. A
Silt Mount Adapter
can be used to mount
the AV|Max sensor 30 degrees up the left side of the pipe (the
7:00 position) when a higher elevation is necessary. However,
keep in mind that a physical offset measurement must be taken
when mounting the sensor in any position outside the bottom
of the pipe. Refer to
Installing the Ring in the Pipe
on page 5-
28.
z
Peak Combo Sensor
Mount the sensor as close as possible
to the six o’clock position (bottom), provided it is mounted
above the level of any silt present at the bottom of the pipe.
Any silt covering the sensor could interfere with the sensor
signals, potentially producing inaccurate or erroneous readings.
A
Silt Mount Adapter
can be used to mount the sensor 30
degrees up the left side of the pipe (7:00 position) when a
higher elevation is necessary. However, keep in mind that a
physical offset measurement must be taken when mounting the
sensor in any position outside the bottom of the pipe. Refer to
Installing the Ring in the Pipe
on page 5-28.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...