Sensor Installation and Connection 5-27
directly at the top. If no ParaDepth, ParaFlow, Surface Combo
sensor or Ultrasonic Depth sensor will be used at the top of the
pipe, make sure the spreader assembly is at the 2:00 or 10:00
position so as not to interfere with the underwater ultrasonic
depth sensor reading in full pipe conditions.
3.
Secure the sensor cable to the ring. Refer to
Securing the
Cables to the Ring
on page 5-27 for instructions on properly
securing the cable.
Securing the Cables to the Ring
Securing the AV|Gated, AV|Max or Peak Combo sensor cables to
the ring helps prevent debris from collecting between the cable and
the ring or catching on the loose cable. It also prevents the loose
cables from disrupting the flow.
Secure the cable in the following way:
1.
Starting at the appropriate sensor location, begin securing the
sensor cable with 4-inch (2-mm x 100-mm) cable ties through
the pre-drilled holes along the downstream trailing edge of the
ring up the side of the ring. Run the cable up the side of the
ring opposite the spreader mechanism (the right side of the
ring’s d
ownstream edge).
Sensor cabling
2.
Continue securing the cables until reaching the ParaDepth,
ParaFlow, Surface Combo sensor, Ultrasonic Depth sensor, or
top of the pipe.
3.
Pull the ties until they are taut.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...