System Overview
2-29
board and the value is sent to the monitor processor board. A vent
tube on the back of the diaphragm equalizes for atmospheric
pressure. Three versions of pressure transducers are available with
this combo sensor: 0 - 5 PSI (0 - 0.34 Bar), 0 - 15 PSI (0 - 1.03
Bar), and 0 - 30 PSI (0 - 2.07 Bar).
Peak Velocity Sensor
To obtain peak velocity, this sensor sends an ultrasonic signal at an
angle up through the velocity layers in the oncoming flow. It emits
a wide, omni-directional sound wave at a specific frequency
upward into the flow. The sound wave bounces off particles in the
flow and returns to the sensor. The velocity sensor measures the
change in the sound wave's frequency from transmission to
reception. This change is used to determine the peak velocity of the
flow based on the
Doppler
effect.
Peak Combo sensor Peak Velocity transducer
The Doppler effect describes the shift in frequency of a sound wave
emitted by a moving object in relation to a stationary point. The
moving objects represent particles in the flow, the stationary point
is the velocity sensor, and the signal received is the reflection of the
sound wave (emitted by the velocity sensor) off the particles.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...