Maintenance and Troubleshooting 11-73
Problem
Data or readings received at the monitor through the 4-
20 mA input in the XIO from the customer output device
are not accurate or were unexpected.
Possible
Causes
Wiring from XIO analog input to external 4-20 mA output
device may not be properly connected.
XIO Device
may not have been properly configured
through
Q
start
XML
.
Analog module in XIO may not have been setup properly
or may be defective.
Possible
Solutions
Verify wiring between the XIO input and the external
output device has been properly connected.
Verify that the correct analog input entity has been
selected, the scale has been set properly, and the
appropriate data checkboxes have been selected in
Q
start
XML
. If necessary, adjust the configuration and
reactivate the monitor.
Contact your regional ADS representative.
Problem
Data received at the monitor through the digital input in
the XIO from the customer output device is not
consistent with output.
Possible
Causes
XIO Device
may not have been properly configured in
Q
start
XML
for the digital input.
Possible
Solutions
Verify that the
D1
(or
D2
) entity and the
Store Data
checkbox have been selected for the appropriate digital
input from the
XIO Device
configuration in
Q
start
XML
.
If changes are required, reactivate the monitor. (
Note:
The
D1
corresponds to digital output 1 and
D2
corresponds to digital output 2.)
Contact your regional ADS representative.
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...