6-4 ADS
TRITON
+ Manual
x
Monitor Firing Sensors during Measurement Cycle
without Wireless Communications 110 mA
x
Monitor Firing Sensors during Measurement Cycle
with Wireless Communications Idle 140 mA
x
Monitor Firing Sensors during Measurement Cycle
with Wireless Communications Active (<10
milliseconds) 360 mA
x
Wireless Modem Communications Idle 110 mA
x
Wireless Modem during Data Collection (147 blocks
of data over 150 seconds) 130 mA
x
RS-485 (ExPAC) Modbus Communications (updating
every 2 seconds) 81 mA
x
USB (ExPAC) Communications Idle 86 mA
x
USB (ExPAC) Communications during Data
Collection (147 blocks of data over 50 seconds) 90
mA
Note:
Measurement cycle involves firing Peak Combo
Sensor and Surface Combo Sensor and running MLI.
Mounting the XIO or XBUS
Note:
These instructions apply only to applications
involving an XIO or XBUS. If the monitor will not
receive external power through an XIO or XBUS, proceed
to the next section,
Mounting the Recommended Power
Supply
.
Mount and secure the XIO or XBUS in such a way that takes into
account the specific environment in which it will be located. For
outdoor
installation, mount it in such a way that will provide the
best protection against the elements and excessive heat or cold.
The operating temperature range for the XIO/XBUS is -14
q
to 122
q
F (-10
q
to 50
q
C). Locate the enclosure under an awning or other
structure to prevent direct sun exposure. For
indoor
installation,
Содержание 507165
Страница 20: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Страница 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Страница 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Страница 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Страница 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Страница 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Страница 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Страница 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Страница 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Страница 53: ...System Overview 2 13 ExPAC XBUS ...
Страница 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Страница 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Страница 292: ...5 86 ADS TRITON Manual Confirm Level Front to Back Installed ParaDepth ParaFlow Wall Mount Bracket ...
Страница 315: ...External Power 6 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 327: ...External Power 6 21 Wires exiting DC output terminal on power supply POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS ...
Страница 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Страница 358: ...Inclinometer 8 3 ...
Страница 507: ...C 4 ADS TRITON Manual ...
Страница 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...