Example 2:
Linear axis application
Two conveyer systems are synchronised using two encoders. The follower is in
synchron control and follows the master encoder 2 position.
Note:
In linear axis applications, only the difference between the master and follower
positions is corrected.
Parameter
Setting
Information
Positioning between minimum position
and maximum position
All position values are in metres
Synchron position reference (master position) from
encoder 2.
Absolute synchronisation of the follower. The follower
follows the master position after start.
Cyclic master follower distance correction
Rising edge of encoder 1 digital input DI1.
Source of the actual position latching command
(proximity switch signal source)
Rising edge of encoder 2 digital input DI2.
Source of the master position reference latching
command (proximity switch signal source)
0,015 m
Reference position for the actual position probe
0,025 m
Reference position for the master position probe
M
3~
M
3~
Encoder DI2 (
MASTER
FOLLOWER
10 mm
Encoder DI1 (
Encoder 2
Encoder 1
Proximity switch
Proximity switch
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...