![ABB ACSM1 Series Скачать руководство пользователя страница 310](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326310.webp)
Fault tracing
310
2027
FEN TEMP MEAS
FAILURE
(0x7385)
Error in temperature
measurement when
temperature sensor (KTY or
PTC) connected to encoder
interface FEN-xx is used.
Check that parameter
setting corresponds to encoder
interface installation (
/
):
If one FEN-xx module is used:
- Parameter
setting must be either
. FEN-xx module can be in
either Slot 1 or Slot 2.
If two FEN-xx modules are used:
- When parameter
setting is
, the encoder installed in drive
Slot 1 is used.
- When parameter
setting is
, the encoder installed in drive
Slot 2 is used.
Error in temperature
measurement when KTY
sensor connected to encoder
interface FEN-01 is used.
FEN-01 does not support temperature
measurement with KTY sensor. Use PTC
sensor or other encoder interface module.
2028
ENC EMUL MAX FREQ
(0x7386)
TTL pulse frequency used in
encoder emulation.exceeds
maximum allowed limit
(500 kHz).
Decrease parameter
value.
Note:
The new setting will only take effect
after parameter
used or after the JCU control unit is powered
up the next time.
2029
ENC EMUL REF ERROR
(0x7387)
Encoder emulation has failed
due to failure in writing new
(position) reference for
emulation.
Contact your local ABB representative.
2030
RESOLVER AUTOTUNE
ERR
(0x7388)
Resolver autotuning routines,
which are automatically started
when resolver input is activated
for the first time, have failed.
Check cable between resolver and resolver
interface module (FEN-21) and order of
connector signal wires at both ends of cable.
Check resolver parameter settings.
For resolver parameters and information, see
parameter group
on page
.
Note:
Resolver autotuning routines should
always be performed after resolver cable
connection has been modified. Autotuning
routines can be activated by setting
parameter
or
, and then setting
parameter
Code
Alarm
(fieldbus code)
Cause
What to do
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...