Fault tracing
322
0040
ENCODER2
(0x7381)
Encoder 2 feedback fault
See fault ENCODER1.
EnDat or SSI encoder is used in
continuous mode as encoder 2.
[I.e.
=
and
or
and
=
=
).]
If possible, use single position transfer
instead of continuous position transfer (i.e. if
encoder has incremental sin/cos signals):
- Change parameter
/
to value
Otherwise use Endat/SSI encoder as
encoder 1:
- Change parameter
and parameter
Note:
The new setting will only take effect
after parameter
used or after the JCU control unit is powered
up the next time.
0041
POSITION ERROR
(0x8500)
Calculated position error,
, exceeds defined
position error supervision
window. Motor is stalled.
Check supervision window setting, parameter
Check that no torque limit is exceeded during
positioning.
0043
POSITION ERROR MIN
(0x8582)
Actual position value exceeds
defined minimum position
value.
Check minimum position setting, parameter
Limit can be exceeded because
no homing (or preset function)
has been performed.
Perform homing (or preset function).
0044
POSITION ERROR MAX
(0x8583)
Actual position value exceeds
defined maximum position
value.
Check maximum position setting, parameter
.
Limit can be exceeded because
no homing (or preset function)
has been performed.
Perform homing (or preset function).
0045
FIELDBUS COMM
(0x7510)
Programmable fault:
Cyclical communication
between drive and fieldbus
adapter module or between
PLC and fieldbus adapter
module is lost.
Check status of fieldbus communication. See
appropriate User’s Manual of fieldbus adapter
module.
Check fieldbus parameter settings. See
parameter group
on page
.
Check cable connections.
Check if communication master can
communicate.
0046
FB MAPPING FILE
(0x6306)
Drive internal fault
Contact your local ABB representative.
Code
Fault
(fieldbus code)
Cause
What to do
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...