![ABB ACSM1 Series Скачать руководство пользователя страница 257](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326257.webp)
Parameters and firmware blocks
257
(7)
FEN-31 HTL
Communication active. Module type: FEN-31 HTL Encoder Interface.
Input: HTL encoder input (X82). See parameter group
90.02
ENCODER 2 SEL
(see above)
Activates the communication to the optional encoder/resolver interface 2.
For selections, see parameter
Note:
The counting of full shaft revolutions is not supported for encoder 2.
90.03
EMUL MODE SEL
(see above)
Enables the encoder emulation and selects the position value and the TTL output used in the
emulation process.
In encoder emulation, a calculated position difference is transformed to a corresponding number of
TTL pulses to be transmitted via the TTL output. The position difference is the difference between the
latest and the previous position values.
The position value used in emulation can be either a position determined by the drive software or
a position measured by an encoder. If drive software position is used, the source for the used position
is selected by parameter
. Because the software causes a delay, it is
recommended that actual position is always taken from an encoder. Drive software is recommended
to be used only with position reference emulation.
Encoder emulation can be used to increase or decrease the pulse number when TTL encoder data is
transmitted via the TTL output, eg, to another drive. If the pulse number requires no alternation, use
encoder echo for data transformation. See parameter
Note:
If encoder
emulation and echo are enabled for the same FEN-xx TTL output, the emulation overrides the echo.
If an encoder input is selected as emulation source, the corresponding selection must be activated
either with parameter
The TTL encoder pulse number used in emulation must be defined by parameter
.
(0)
Disabled
Emulation disabled.
(1)
FEN-01 SWref
Module type: FEN-01 TTL Encoder interface Module. Emulation: Drive
software position (source selected by par.
emulated to FEN-01 TTL output.
(2)
FEN-01 TTL+
Module type: FEN-01 TTL Encoder interface Module. Emulation: FEN-
01 TTL encoder input (X32) position is emulated to FEN-01 TTL
output.
(3)
FEN-01 TTL
Module type: FEN-01 TTL Encoder interface Module. Emulation: FEN-
01 TTL encoder input (X31) position is emulated to FEN-01 TTL
output.
(4)
FEN-11 SWref
Module type: FEN-11 Absolute Encoder Interface. Emulation: Drive
software position (source selected by par.
emulated to FEN-11 TTL output.
(5)
FEN-11 ABS
Module type: FEN-11 Absolute Encoder Interface. Emulation: FEN-11
absolute encoder input (X42) position is emulated to FEN-11 TTL
output. Emulation is not possible with SSI or EnDat in the Continuous
mode (parameters
and
(6)
FEN-11 TTL
Module type: FEN-11 Absolute Encoder Interface. Emulation: FEN-11
TTL encoder input (X41) position is emulated to FEN-11 TTL output.
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...