![ABB ACSM1 Series Скачать руководство пользователя страница 337](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326337.webp)
Standard function blocks
337
Outputs
Output (O): INT, DINT
ROR
(10014)
Illustration
Execution time
1.28 µs
Operation
Input bits (I) are rotated to the right by the number (N) of bits defined by BITCNT. The N
least significant bits (LSB) of the input are stored as the N most significant bits (MSB) of
the output.
Example: If BITCNT = 3
Inputs
The input data type is selected by the user.
Number of bits input (BITCNT): INT, DINT
Input (I): INT, DINT
Outputs
Output (O): INT, DINT
SHL
(10015)
Illustration
Execution time
0.80 µs
Operation
Input bits (I) are rotated to the left by the number (N) of bits defined by BITCNT. The N
most significant bits (MSB) of the input are lost and the N least significant bits (LSB) of
the output are set to 0.
Example: If BITCNT = 3
ROR
(DINT)
60
TLA1 1 msec
(1)
BITCNT
I
O
O(60)
I
1 1 1 0 0 0 0 0 1 1 1 0 0 1 0 1 1 1 0 1 0 0 1 1 0 0 1 1 0 1 0 1
O
1 0 1 1 1 1 0 0 0 0 0 1 1 1 0 0 1 0 1 1 1 0 1 0 0 1 1 0 0 1 1 0
3 MSB
3 LSB
SHL
(DINT)
61
TLA1 1 msec
(1)
BITCNT
I
O
O(61)
I
1 1 1 0 0 0 0 0 1 1 1 0 0 1 0 1 1 1 0 1 0 0 1 1 0 0 1 1 0 1 0 1
O
0 0 0 0 0 1 1 1 0 0 1 0 1 1 1 0 1 0 0 1 1 0 0 1 1 0 1 0 1 0 0 0
3 MSB
3 LSB
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...