![ABB ACSM1 Series Скачать руководство пользователя страница 222](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326222.webp)
Parameters and firmware blocks
222
60.12
POS SPEED SCALE
(see above)
Defines an additional scaling for internal positioning speed, acceleration and deceleration values. Can
be used, eg, to improve calculation accuracy at low and high speeds.
Example: If parameter value is set to 0.1, internal speed value 1 rev/s is changed to value 10 rev/s.
0…32768
Additional scaling factor.
60.13
MAXIMUM POS
(see above)
Defines the maximum position value. If the actual position value exceeds the maximum position limit,
fault message POSERR MAX is generated.
The unit depends on parameter
selection.
0…32768
Maximum position value.
60.14
MINIMUM POS
(see above)
Defines the minimum position value. If the actual position value falls below the minimum position limit,
fault message POSERR MIN is generated.
The unit depends on parameter
selection.
-32768…0
Minimum position value.
60.15
POS THRESHOLD
(see above)
Defines the position threshold supervision limit. If actual position
exceeds the defined
limit,
bit 10 ABOVE THRES is activated.
The unit depends on parameter
selection.
-32768…32768
Position threshold supervision limit.
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...