![ABB ACSM1 Series Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326081.webp)
Drive control and features
81
Distance correction with two probes
The purpose is to measure the distance between two consecutive latches from two
probes and compare it with the distance between the reference positions
. If there is a deviation, a corresponding
correction is carried out on the drive actual position
. The latches use
different latch sources (eg, encoder interface digital inputs DI1 and DI2) and latch
commands (eg, rising and falling edge).
In special applications, this correction function can also be executed by using two
consecutive latches from one probe. The latches use the same latch source (eg,
encoder digital input DI1) and different latch commands (eg, rising and falling edge).
Example:
The following figure shows a conveyer system where a box should be positioned.
The conveyer belt is marked every 60 mm.
Parameter
Setting
Information
Positioning between minimum position
MINIMUM POS and maximum position
MAXIMUM POS
All position values are in metres
CYCLIC CORR MODE (4) 2 Probe Dist
Distance correction with two probes
Rising edge of encoder 1 digital input DI1.
Source of the actual position latching command
(proximity switch signal source)
Falling edge of encoder 1 digital input DI2.
Source of the actual position reference latching
command (proximity switch signal source)
0 m
Reference position for actual position probe 1
0.060 m (=60 mm)
Reference position for actual position probe 2
M
3~
60 mm
ENCODER
GEARBOX
MOTOR
PROXIMITY SWITCHES
Encoder DI1
Encoder DI2
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...