Parameters and firmware blocks
194
45.06
MOT LOAD CURVE
(see above)
Defines the load curve together with parameters
and
.
The value is given in percent of nominal motor current. When the parameter is set to 100%, the
maximum load is equal to the value of the parameter
(higher loads heat
up the motor). The load curve level should be adjusted if the ambient temperature differs from the
nominal value.
The load curve is used by the motor thermal protection model when parameter
.
50…150%
Motor current above breakpoint.
45.07
ZERO SPEED LOAD
(see above)
Defines the load curve together with parameters
and
. Defines the maximum motor load at zero speed of the load curve. A higher value can be used
if the motor has an external motor fan to boost the cooling. See the motor manufacturer's
recommendations.
The value is given in percent of nominal motor current.
The load curve is used by the motor thermal protection model when parameter
.
50…150%
Motor current at zero speed.
45.08
BREAK POINT
(see above)
Defines the load curve together with parameters
. Defines the break point frequency of the load curve, ie, the point at which the motor load curve
begins to decrease from the value of parameter
to the value of parameter
.
The load curve is used by the motor thermal protection model when parameter
.
0.01…500 Hz
Load curve breakpoint.
50
100
150
I/I
N
(%)
I
= Motor current
I
N
= Nominal motor current
Drive output frequency
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...