Parameters and firmware blocks
100
2.17
D2D MAIN CW
(page
Drive-to-drive control word received through the drive-to-drive link. See also actual signal
below.
2.18
D2D FOLLOWER CW
(page
)
Drive-to-drive control word sent to the followers by default. See also firmware block
on page
2.19
D2D REF1
(page
Drive-to-drive reference 1 received through the drive-to-drive link.
2.20
D2D REF2
(page
Drive-to-drive reference 2 received through the drive-to-drive link.
Bit
Information
0
Stop.
1
Start.
2…6 Reserved.
7
Run enable. By default, not connected in a follower drive.
8
Reset. By default, not connected in a follower drive.
9…14 Freely assignable through bit pointer parameters.
15
EXT1/EXT2 selection. 0 = EXT1 active, 1 = EXT2 active. By default, not connected in a
follower drive.
Bit
Information
0
Stop.
1
Start.
2…6 Reserved.
7
Run enable.
8
Reset.
9…14 Reserved.
15
EXT1/EXT2 selection. 0 = EXT1 active, 1 = EXT2 active.
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...