Standard function blocks
399
Selection
LIMIT
(10052)
Illustration
Execution time
0.53 µs
Operation
The output (OUT) is the limited input (IN) value. Input is limited according to the
minimum (MN) and maximum (MX) values.
Inputs
The input data type is selected by the user.
Minimum input limit (MN): INT, DINT, REAL, REAL24
Input (IN): INT, DINT, REAL, REAL24
Maximum input limit (MX): INT, DINT, REAL, REAL24
Outputs
Output (OUT): INT, DINT, REAL, REAL24
MAX
(10053)
Illustration
Execution time
0.81 µs (when two inputs are used) + 0.53 µs (for every additional input). When all
inputs are used, the execution time is 16.73 µs.
Operation
The output (OUT) is the highest input value (IN).
Inputs
The input data type and the number of inputs (2…32) are selected by the user.
Input (IN1…IN32): INT, DINT, REAL, REAL24
Outputs
Output (OUT): INT, DINT, REAL, REAL24
MIN
(10054)
Illustration
Execution time
0.81 µs (when two inputs are used) + 0.52 µs (for every additional input). When all
inputs are used, the execution time is 16.50 µs.
LIMIT
(DINT)
76
TLA1 1 msec
(1)
MN
IN
MX
OUT
OUT(76)
MAX
(DINT)
77
TLA1 1 msec
(1)
IN1
IN2
OUT
OUT(77)
MIN
(DINT)
78
TLA1 1 msec
(1)
IN1
IN2
OUT
OUT(78)
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...