Appendix C – Homing methods
486
Homing method 33
The status of the home switch at start is insignificant.
Homing method 34
The status of the home switch at start is insignificant.
Homing method 35
In method 35 the current position is used as home position.
1
Start in the negative (left) direction by the rising edge of the signal selected by par.
with homing speed 1, par.
2
Stop by the next index pulse.
1
2
Homing method 33
Homing start (par.
Index pulse
1
Start in the positive (right) direction by the rising edge of the signal selected by par.
with homing speed 1, par.
2
Stop by the next index pulse.
1
2
Homing method 34
)
Index pulse
Содержание ACSM1 Series