Parameters and firmware blocks
193
(1)
KTY JCU
The temperature is supervised using a KTY84 sensor connected to
drive thermistor input TH.
(2)
KTY 1st FEN
The temperature is supervised using a KTY84 sensor connected to
encoder interface module FEN-xx installed in drive Slot 1/2. If two
encoder interface modules are used, encoder module connected to
Slot 1 is used for the temperature supervision.
Note:
This selection
does not apply for FEN-01. *
(3)
KTY 2nd FEN
The temperature is supervised using a KTY84 sensor connected to
encoder interface module FEN-xx installed in drive Slot 1/2. If two
encoder interface modules are used, encoder module connected to
Slot 2 is used for the temperature supervision.
Note:
This selection
does not apply for FEN-01. *
(4)
PTC JCU
The temperature is supervised using 1…3 PTC sensors connected to
drive thermistor input TH.
(5)
PTC 1st FEN
The temperature is supervised using 1…3 PTC sensors connected to
encoder interface module FEN-xx installed in drive Slot 1/2. If two
encoder interface modules are used, encoder module connected to
Slot 1 is used for the temperature supervision. *
(6)
PTC 2nd FEN
The temperature is supervised using 1…3 PTC sensors connected to
encoder interface module FEN-xx installed in drive Slot 1/2. If two
encoder interface modules are used, encoder module connected to
Slot 2 is used for the temperature supervision. *
*Note:
If one FEN-xx module is used, parameter setting must be either
. The FEN-xx module can be in either Slot 1 or Slot 2.
45.03
MOT TEMP ALM LIM
(see above)
Defines the alarm limit for the motor overtemperature protection (when par.
=
or
).
0…200 °C
Motor overtemperature alarm limit.
45.04
MOT TEMP FLT LIM
(see above)
Defines the fault limit for the motor overtemperature protection (when par.
MOT TEMP PROT =
0…200 °C
Motor overtemperature fault limit.
45.05
AMBIENT TEMP
(see above)
Defines the ambient temperature for the thermal protection mode.
-60…100 °C
Ambient temperature.
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...