Fault tracing
318
0019
CURR V2 MEAS
(0x3185)
Measured offset error of V2
output phase current
measurement is too great.
(Offset value is updated during
current calibration.)
Contact your local ABB representative.
0020
CURR W2 MEAS
(0x3186)
Measured offset error of W2
output phase current
measurement is too great.
(Offset value is updated during
current calibration.)
Contact your local ABB representative.
0021
STO1 LOST
(0x8182)
Safe Torque Off function is
active, i.e. safety circuit signal 1
connected between X6:1 and
X6:3 is lost while drive is at
stopped state and parameter
setting is
or
.
Check safety circuit connections. For more
information, see the appropriate drive
hardware manual and
Application guide -
Safe torque off function for ACSM1, ACS850
and ACQ810 drives
(3AFE68929814
[English]).
0022
STO2 LOST
(0x8183)
Safe Torque Off function is
active, i.e. safety circuit signal 2
connected between X6:2 and
X6:4 is lost while drive is at
stopped state and parameter
setting is
or
.
Check safety circuit connections. For more
information, see the appropriate drive
hardware manual and
Application guide -
Safe torque off function for ACSM1, ACS850
and ACQ810 drives
(3AFE68929814
[English]).
0024
INTBOARD OVERTEMP
(0x7182)
Interface board (between power
unit and control unit)
temperature has exceeded
internal fault limit.
Let drive cool down.
Check for excessive ambient temperature.
Check for cooling fan failure.
Check for obstructions in the air flow.
Check the dimensioning and cooling of the
cabinet.
0025
BC MOD OVERTEMP
(0x7183)
Input bridge or braking chopper
temperature has exceeded
internal fault limit.
Let drive cool down.
Check for excessive ambient temperature.
Check for cooling fan failure.
Check for obstructions in the air flow.
Check the dimensioning and cooling of the
cabinet.
Code
Fault
(fieldbus code)
Cause
What to do
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...