Standard function blocks
352
Conversion
BOOL_TO_DINT
(10018)
Illustration
Execution time
13.47 µs
Operation
The output (OUT) value is a 32-bit integer value formed from the boolean input
(IN1…IN31 and SIGN) values. IN1 = bit 0 and IN31 = bit 30.
Example:
IN1 = 1, IN2 = 0, IN3…IN31 = 1, SIGN = 1
BOOL_TO_DINT
81
TLA1 1 msec
(1)
SIGN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN17
IN18
IN19
IN20
IN21
IN22
IN23
IN24
IN25
IN26
IN27
IN28
IN29
IN30
IN31
OUT
OUT(81)
OUT = 1111 1111 1111 1111 1111 1111 1111 1101
IN31…IN1
SIGN