Start-up
28
How to control the drive through the I/O interface
The table below instructs how to operate the drive through the digital and analogue
inputs, when the default parameter settings are valid.
PRELIMINARY SETTINGS
Ensure the control connections are wired according to the connection
diagram given in chapter
Default connections of the control unit
Switch to external control by clicking the Take/Release button of the PC
tool control panel.
STARTING AND CONTROLLING THE SPEED OF THE MOTOR
Start the drive by switching digital input DI1 on. Digital input status can be
monitored with signal
Check that analogue input AI1 is used as a voltage input (selected by
jumper J1).
Regulate the speed by adjusting the voltage of analogue input AI1.
Check analogue input AI1 signal scaling. AI1 values can be monitored
with signals
and
When AI1 is used as a voltage input, the input is differential and the
negative value corresponds to the negative speed and the positive value
to the positive speed.
…
STOPPING THE MOTOR
Stop the drive by switching digital input DI1 off.
Voltage:
J1
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...